Quote:
Originally Posted by Overboost
I assume you checked the 5V and 0V supply to the connector? If those are there then check the 0V-5V signal on the sensor when rotating the lever.
|
I didn't check that... it was 115 outside (my shops an outdoor shop) so I was kind of eager to get in and out. I was drenched in sweat by the time I was done.
I'm going to re-code the module using NCS expert, then see whats going on with it. If it still isn't working, I'll go back to the shop later and check out the sensor voltage.