Quote:
Originally Posted by Effduration
I use NCS Expert more than Dummy.
So, In NCS Expert, we probably just need to change the following in KOMBI module :
KUEHLMITTELTEMP_ADC_WERT: kennline_03
to:
KUEHLMITTELTEMP_ADC_WERT: kennline_04
And then change MOTOR_UEBERTEMP in LCM as noted
|
Yes that's what has to be done. But as
Clockwork stated you have to check the values match, just in case. And for MOTOR_UEBERTEMP you will certainly need NCS Dummy, because you have to update the DATEN file with the new value 114c celsius. It's an easy to use tool.