Quote:
Originally Posted by neiloakley View Post
So i look up U407 and get Component and signal information>Components>U)Radio/interferance supression equipment>U407 Basic Interface, telephone>U407 Basic Interface Telephone (Fixed Mounting, siemens (cordless handset) from 2002_03)

But i cant find the pin out list for this.
The circuit diagram shows connector numbers, and also shows the connector pins, wire colour, wire size and wire function.
Just click the connector number for a full table.

Quote:
Originally Posted by neiloakley View Post
When i search for the TCU (I01157) it comes up with Components>I_Components of outside manufacturer>I01157 Telematcis Control Unit (TCU_Everest) (without USA_LHD)

and then i can see a table of all the Pin assignments at plug connector X18500

Where can i go from here? The only pin out i can find for BIT2 is X4038
Thats all the info you need.
You see the wiring and signals of the existing BIT2
You see the wiring and signals of the wanted new TCU

Simply transfer the relevant wires from the old to the new

Of course, some will be no longer required, and you may need to reassign some wires running from phone to the eject box.

But it is pretty straight forward.

Work in this order:
Ground
Ibus
Power
Microphone
Audio Out
Eject Box
SOS switch (if fitted)

That's all you need.