Originally Posted by Rockmelon View Post
have you tried refilling the freon? i understand that normal pressure range for inlet & outlet is around 1.5-2.2 bar and 12-22 bar. since driver side is cool and passenger side is warmer, the inlet pressure should be within normal range and outlet pressure should be on the low end. this suggests low freon and a possible leak somewhere. compressor should be fine since driver side is cooling. depending on how fast the same symptom recur after a refill, it just tells how bad the leak is. well i know of folks who would rather spend about $20-40 to refill freon every 2-3 months rather than change a leaking evaporator.
Thanks for the suggestion.

I did have it checked about a month ago so I discounted this as a problem area. However, my mechanic recommended we re-check this and we're going to this morning.

He told me on Wednesday that is what he first suspected and I thought the right side was blowing hot air until I checked it in the morning. It was blowing quite hot the first time I checked on Tuesday evening but it was 90 F outside