Well, I may have spoke too soon. Drive around again today in 90+ degree weather and it acted up a couple times. I did notice that with the air recirc button on the air stayed a similar temp on both sides, but the fan was definitely acting up. It just quit and when I turned up the fan speed, the air did not increase, but I did notice the blower sound increasing.
Two more questions;
How much is excessive condensation under the car? It a medium sized pizza puddle too much?
Also, for Weasel, what is the best method to clean the FSR connection?
|
If the blower speed sound is increasing, just not the actual air speed out of the vents it isn't going to be the FSR... It is going to be either the evaporator freezing up or possibly some flaps acting up somehow. When it stops blowing out of the vents will it blow out of the floor or defrosters? If yes than it is a flaps/control problem. If no airflow out of any vents it is most likely freezing up.
Trying to remember... have you had any other AC work at all done recently? (other than the FSR)