I see the adaption process. But I cant clear my codes to start this process.


"
EDK ADAPTATION
PROCEDURE:
When a replacement EDK
is installed the adaptation
values of the previous EDK
must be cleared from the
ME 7.2 control module.

1. From the Service
Function Menu of the
DIS/MoDiC, clear
adaptation values.

2. Switch the ignition OFF
for 10 seconds.

3. Switch the ignition ON
(KL 15). At approximately
30 seconds the
EDK is briefly activated
allowing the ME 7.2 to
“electrically learn” the
new component.
This procedure is also necessary after replacing an ME 7.2 control module. However, the
adaptation values do not require clearing since they have not yet been established."