View Single Post
  #1  
Old 03-04-2013, 06:25 PM
chauez chauez is offline
Member
 
Join Date: Sep 2012
Location: San Antonio, TX
Posts: 11
chauez is on a distinguished road
140 Output Thermostat Map cooling error in INPA

I have read the forums and when most people recieved this error the solution was to reaplce the thermostat. I used did that and still see the error. This is what I get from INPA. Any ideas?

E R R 0 R MEMORY
Date: 03/02/13 18:30:19
ECU: 11E72KWP1
JobStatus: OKAY
Uariant: ME72KWP1
RESULT: 1 errors in error memory !
140 Output Thermostat Map cooling

Error frequency : 2
Logistic counter: 40

Error occured 1 times at:
Engine speed 600.00
Engine temperature 90.00
Intake air temperature 48.75
Supply uoltage 13.75

Error occured 2 times at:
Engine speed 600.00
Engine temperature 90.00
Intake air temperature 48.75
Supply uoltage 13.47

Error currently available
Error tested
REPORT

Error tested
Signal-/Path discontinuity current,
Signal-/Path discontinuity Initial,
Fault sporadic

And this from DIS

DME - SC DME: Activation, map cooling...
Reply With Quote